EMT Practice Test

1. Question Content...


Question List

Question1: A vSAN administrator, who has a cluster that has both compute-only and vSAN ReadyNodes, recently received a request to deploy a new application with higher storage performance requirements than what are currently available.
What are two ways the administrator can reconfigure the vSAN cluster to obtain this additional performance? (Choose two.)

Question2: Which two characteristics are associated with vSAN Data-In-Transit Encryption? (Choose two.)

Question3: A vSAN administrator was examining the status of Virtual Objects and found inaccessible objects that are occupying significant storage capacity.
Refer to the exhibit:

Which action is needed to restore the storage capacity?

Question4: A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources.
Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)

Question5: A vSAN administrator has recently upgraded a vSAN cluster to 7.0 U1 and has enabled Capacity Reserve features to reduce the amount of capacity reserved for transient and rebuild operations.
Which scenario would prevent this feature from operating properly?

Question6: After a server power failure, the administrator noticed the scheduled resyncing in the cluster monitor displays objects to be resynchronized under the pending category.
What are these objects in this category?

Question7: A vSAN administrator is troubleshooting poor performance of vSAN cluster while vCenter is not available. The vSAN administrator decides to use a command line tool to monitor real-time vSAN IOPS, throughput, and other metrics on ESXi host.
Which command line tool should be used?

Question8: Which solution can automate the deployment of a vSAN cluster as part of a full Software-Defined Datacenter?

Question9: A vSAN administrator is noticing that the objects resynchronizing in the cluster are taking longer than expected and wants to view the resynchronizing metrics.
Which performance category should the vSAN administrator open?

Question10: Which two requirements should the vSAN administrator consider in order to accomplish this goal? (Choose two.)

Question11: An administrator is responsible for managing a 5-node vSAN 7.0 cluster that hosts 150 virtual machines. Each virtual machine belongs to one of the following vSAN Storage Policies:
vSANPolicy1:
Site Disaster Tolerance: None
Failures to Tolerate: 1 failure - RAIN5 (Erase Coding)
vSANPolicy2:
Site Disaster Tolerance: None
Failures to Tolerate: No data redundancy
Following an unplanned power event within the datacenter, the administrator has been alerted to the fact that one host has permanently failed. Prior to the vSAN host failure, the usable storage capacity of the vSAN Cluster was more than 40%.
What will be the potential impact to any virtual machine that was running on the failed host using vSANPolicy2?

Question12: Which vSAN advanced setting can be adjusted to avoid rebuild operations during a host hardware maintenance window that is expected to exceed 90 minutes?

Question13: A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the cluster are compliant according to the vLCM image.
A 10GB NIC on the servers is experiencing issues, the vSAN administrator determines a new network driver will resolve the problem. Unfortunately, the required NIC driver is a newer version compared to the driver provided by the most recent Vendor Addon.
Which action should the vSAN administrator take to ensure the latest network driver is installed on the NIC before remediation?

Question14: A vSAN administrator is receiving complaints that applications are not performing as expected. The vSAN administrator opens the vSAN cluster performance charts to try to identify the issue, but the vSAN cluster performance charts are not available.
Which option should vSAN administrator enable to make these charts available?

Question15: Which two prerequisites are required before a vSAN administrator is able to use the vSAN Performance Diagnostics feature? (Choose two.)

Question16: Which state is NOT a compliance status of a VM Storage Policy?

Question17: A vSAN administrator is implementing deduplication and compression on a vSAN all-flash cluster but wants the VMs to remain operational. The details are as follows:
There are 4 nodes in the vSAN cluster.
Existing VMs use a RAID-5 storage policy.
Which action should the vSAN administrator take to meet this goal?

Question18: A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task.
What is the fastest approach?

Question19: Which two conditions should be verified before removing an ESXi host from a vSAN cluster? (Choose two.)

Question20: Which Storage Policy Structure Rule is supported by vSAN Direct Datastore?

Question21: A single capacity disk fails within a vSAN 7.0 U1 cluster running with a "compression-only" configuration enabled. The vSAN administrator must recognize the platform impact that has occurred and take steps to correct it.
Which action should the vSAN administrator take?

Question22: A vSAN administrator has been asked to encrypt all traffic for data and metadata across all hosts in a vSAN cluster.
Which action is necessary to achieve this level of encryption?

Question23: Which VM file type resides in the VM home namespace object on a vSAN datastore?

Question24: Which tool should be used to identify vSAN unassociated objects?

Question25: A 100GB virtual disk object has this storage policy assigned to it:
Site disaster tolerance: None - standard cluster
Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
Number of disk stripes per object: 3
What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?

Question26: A vSAN administrator wants to install a patch on an existing vSAN cluster. The environment runs vSphere 7.0, and the patch contains ESXi 7.0 Update 1c. The vSAN administrator will use vSphere Lifecycle Manager images to add the patch to the proper image and apply it to the vSAN cluster.
Which action should be performed before patching the ESXi hosts in the vSAN cluster?

Question27: A newly deployed vSAN cluster runs vSAN 7.0, and the vSAN cluster needs an integration with a third-party software solution. The software solution provides full app-level redundancy, and it runs on the vSAN Data Persistence platform.
The administrator configures vSAN Direct Configuration to integrate the third-party storage with vSAN and now needs to configure a storage policy to make sure the vSAN Direct storage is used by the vSAN Data Persistence platform third-party software solution.
Which type of storage policy configuration should the administrator use?